(a) With θ=0,
h=ρga2Scosθ=1000×9.8×2.5×10−42×0.0727=5.93×10−2 m=5.93 cm
(b) For θ=0 the meniscus is a hemisphere of radius a, concave upwards. The pressure on the concave (air) side is higher than on the convex (water) side by 2S/a:
a2S=2.5×10−42×0.0727=581.6 Pa,PA=Pa−a2S=1.013×105−581.6=1.0072×105 Pa
This lower pressure is what holds the column up. As a check, going down a depth h from A to the level of the outside water surface, the pressure rises by ρgh=1000×9.8×0.0593=581.6 Pa and becomes Pa, the same as at the open water surface at that level, as it must for water at rest.
(c) Mass of the column:
m=ρπa2h=1000×π×(2.5×10−4)2×5.93×10−2=1.17×10−5 kg
Its weight is mg=1.17×10−5×9.8=1.14×10−4 N. The surface tension acts along the circle where the water meets the glass, of length 2πa, and for θ=0 it pulls vertically upwards:
F=2πaS=2π×2.5×10−4×0.0727=1.14×10−4 N
The two are equal: the surface-tension pull supports exactly the weight of the raised column.
(d) From a=ρgh2S:
a=1000×9.8×0.102×0.0727=1.48×10−4 m=0.148 mm
For hot water in the original tube, h∝S/ρ:
hhot=958×9.8×2.5×10−42×0.0589=5.02×10−2 m=5.02 cm
Hot water rises lower. A smaller density alone would raise the column (less weight to support), but S falls by 19% while ρ falls by only 4%, so the weaker pull wins.