(a) The gauge pressure at the base is ρgh=1000×9.8×2.0=1.96×104 Pa, the same everywhere on the flat base. The base area is πR2=π×0.502=0.785 m2, so
Fbase=ρghπR2=1.96×104×0.785=1.54×104 N
(b) On the wall the gauge pressure grows linearly with depth, from 0 at the surface to ρgh at the bottom, and every horizontal strip of the wall has the same area. So the average pressure on the wall is the average of 0 and ρgh:
Pˉ=2ρgh=9.8×103 Pa
The curved wall has area 2πRh=2π×0.50×2.0=6.28 m2, so
Fwall=2ρgh×2πRh=πρgRh2=9.8×103×6.28=6.16×104 N
These forces all point outwards, in different horizontal directions, so they cancel as a vector sum; but each part of the wall must withstand its share. The total is four times the force on the base.
(c)
FbaseFwall=πρgR2hπρgRh2=Rh
The two are equal only when h=R. For a tank deeper than its radius, as here (h/R=4), the walls carry the larger total force.
(d) The volume is πR2h=π×0.502×2.0=0.50π m3, so in the wider tank the depth is
h′=π×1.020.50π=0.50 m
Fbase′=ρgh′πR′2=1000×9.8×0.50×π×1.02=1.54×104 N
Fwall′=πρgR′h′2=π×1000×9.8×1.0×0.502=7.70×103 N
The force on the base is unchanged, because the base (which has vertical walls above it) carries the whole weight of the water, ρgV. The wall force falls from 6.16×104 N to 7.70×103 N, eight times smaller, and Fwall′/Fbase′=h′/R′=0.5. The wall force grows as Rh2: halving the radius of a given volume of water makes it four times deeper, and both the pressure on the wall and the height of wall it acts on grow with the depth. A wide, shallow tank therefore puts far less load on its walls than a narrow, deep one.