Solution:
Concept: A three-pin plug has a top pin for earth (E), longer and thicker than the other two. Seen from the pin side, the pin on the left is live (L) and the pin on the right is neutral (N). The socket is the mirror image: seen from the front, the big top hole is earth, the right hole is live and the left hole is neutral. Each wire of a three-core cable has its own colour of insulation. In the new international convention the live wire is brown, the neutral is light blue and the earth is green with yellow stripes; in the old convention they were red, black and green. In earthing, the metal case of an appliance is joined to the earth wire, whose resistance is almost zero. If a fault makes the live wire touch the case, a very large current flows from the live wire through the case to the earth, and the fuse in the live wire blows at once.
Step 1 — Read the terminals.
On the reverse (wiring) side of a three-pin plug the top terminal belongs to the thick earth pin; the live terminal is on the right and the neutral terminal on the left. In the old colour code the red wire is live, the green wire is earth and the blue wire is neutral.
Step 2 — Find the fault (part a).
The red live wire is on the top (earth) terminal and the green earth wire is on the right-hand (live) terminal: the live and the earth wires are interchanged. The blue neutral wire is on the correct terminal.

Step 3 — Find the risk (part b).
The green wire goes to the metal body of the appliance. With this wiring it carries the live potential (220 V) to the body, so anyone touching the appliance can get a severe, even fatal, shock; the appliance has also lost its earthing protection.
Step 4 — Decide whether it works (part c).
The red wire, which should bring the supply to the appliance's switch and element, is now on the earth pin, at zero potential, and the blue wire is on the neutral pin, also at zero potential. With no potential difference across the element, no current flows, so the appliance does not work.
Watch out: From the back of the plug, live is on the RIGHT; from the pin side it is on the left.
Therefore, (a) the live (red) and earth (green) wires are interchanged; (b) the metal body is at 220 V, so the user can get a fatal shock; (c) No, the appliance will not work.