Solution:
Concept: A dual control switch is a two-way switch: its lever joins its middle (common) terminal to one of two connecting wires that run between the two switches. The bulb glows only when both levers rest on the same connecting wire, so either switch can turn the bulb on or off. Only the live wire is at a high potential (220 V); the neutral and the earth are at 0 V. A device that is meant to make an appliance safe (a fuse, an MCB or a switch) must therefore cut it off from the live wire.
Step 1 — Check both circuits (part a).
In each circuit the two connecting wires join the outer terminals of one switch to the outer terminals of the other (straight in A, crossed in B). Moving either lever always moves its middle terminal from one connecting wire to the other, so in both circuits either switch turns the bulb on or off.
Step 2 — Circuit A now (part b).
The left lever is on the top terminal and the right lever on the bottom terminal. The top and bottom terminals are joined straight across, so the levers are on different wires and the circuit is broken.
Step 3 — Circuit B now (part b).
The right lever is on the bottom terminal, and the crossed wire joins that bottom terminal to the top terminal of the left switch, where the left lever rests. The path L → right switch → crossed wire → left switch → bulb → N is complete, so the bulb in circuit B glows.

Step 4 — Swap L and N in circuit B (part c).
The bulb still glows and can still be switched on and off from both places, because the supply is a.c. and the bulb glows whichever way the current flows. But the circuit is unsafe: the switches are now in the neutral wire, so when the bulb is switched off it is still joined to the live wire, and touching the holder can give a shock.
Watch out: 'Works' and 'safe' are different questions: with L and N swapped the circuit works but is not safe.
Therefore, (a) both circuits A and B; (b) the bulb glows in circuit B; (c) yes, it still works, but it is unsafe because the switches are then in the neutral wire.