(a)
R100=100(1+3.9×10−3×100−5.8×10−7×1002)=100(1+0.39−0.0058)=138.42 Ω
(b) At 50 ∘C: R50=100(1+0.195−0.00145)=119.355 Ω. The linear platinum scale divides the change of 38.42 Ω between the fixed points into 100 equal steps:
tPt=R100−R0R50−R0×100=38.4219.355×100=50.38
so the platinum scale reads about 0.4 degree high.
(c) At the ice and steam points the two scales agree by definition, since both were fixed there. In between, the platinum scale assumes that resistance is a linear function of temperature, but the Bt2 term makes the true curve bend (resistance rises a little faster at low temperatures here), so equal changes in resistance are not equal changes in Celsius temperature. Any thermometric property (length of a liquid column, resistance, gas pressure) varies only approximately linearly with temperature, and each in its own way, so scales based on different properties agree only at their fixed points. That is why a standard is needed; the text uses the gas thermometer at low density, whose readings do not depend on the gas.