A copper connecting wire is to be replaced by an aluminium wire of the same length and the same resistance. The resistivities in NCERT Table 11.2 are: copper m, aluminium m.
How must the aluminium wire compare with the copper wire?
Confirming your payment
Competency-Based Questions (CBQ) · Question 5 of 80
A copper connecting wire is to be replaced by an aluminium wire of the same length and the same resistance. The resistivities in NCERT Table 11.2 are: copper m, aluminium m.
How must the aluminium wire compare with the copper wire?
(A) It must have the same area of cross-section.
(B) It must be thinner.
(C) It must have about 1.6 times the area of cross-section.
(D) It must have about 2.6 times the area of cross-section.
Option (C) is correct.
Explanation: For the same resistance and the same length, gives the same for both wires, so the area must be proportional to the resistivity:
Aluminium has the higher resistivity, so its wire must be thicker to make up for it.
(A) would give the aluminium wire a higher resistance. (B) makes the difference worse. (D) uses aluminium's resistivity on its own instead of the ratio of the two.