A moving coil galvanometer of resistance produces a full scale deflection for a current of . How will you convert it into an ammeter having a range of ?
Previous Year Questions · Question 7 of 10
A moving coil galvanometer of resistance 55 produces a full scale deflection for a current of 250 mA .
Solution:
Key idea: A galvanometer gives full-scale deflection for a small current . To make it an ammeter of range , a low resistance , called a shunt, is connected in parallel with its coil. The shunt carries the extra current , and because and are in parallel they have the same potential difference across them.
Step 1 — Write the data in S.I. units.
The coil resistance is .
The full-scale current is , so in amperes .
The required range is .
Step 2 — Find the current through the shunt.
The shunt must carry the rest of the current.
Step 3 — Equate the voltages and find .
Since and are in parallel, .