Why are the pole pieces of a horseshoe magnet in moving coil galvanometer made cylindrical in shape?
Previous Year Questions · Question 4 of 10
Why are the pole pieces of a horseshoe magnet in moving coil galvanometer made cylindrical in shape?
Solution:
Key idea: The deflecting torque on the coil is , where is the angle between the normal to the coil and the field. For the deflection to be proportional to the current, must stay equal to 1 in every position of the coil.
Step 1 — Say what the cylindrical shape does.
The pole pieces are made concave (cylindrical), and a soft-iron cylinder is placed at the centre between them. This makes the magnetic field in the gap radial: the field lines point along radii, towards or away from the axis of the coil.

Step 2 — Explain why this is needed.
In a radial field the plane of the coil always lies along the field lines, whatever the deflection. So the normal to the coil is always perpendicular to the field, , and the torque is always . Balancing it against the spring's restoring torque gives a deflection , which is proportional to the current.
Therefore, the pole pieces are made cylindrical (concave) to produce a radial magnetic field, so that the torque on the coil is always and the galvanometer has a linear (evenly spaced) scale.