Solution:
Concept: Only the live wire is at a high potential (220 V); the neutral and the earth are at 0 V. A device that is meant to make an appliance safe (a fuse, an MCB or a switch) must therefore cut it off from the live wire. A fuse is a safety device that works on the heating effect of current. It is a short piece of thin wire of a tin–lead alloy, of high resistance and low melting point (about 250 °C), joined in series in the live wire. When the current goes above its current rating, it heats up, melts and breaks the circuit. A dual control switch is a two-way switch: its lever joins its middle (common) terminal to one of two connecting wires that run between the two switches. The bulb glows only when both levers rest on the same connecting wire, so either switch can turn the bulb on or off.
Step 1 — Find which wire carries the switches (part a1).
Both two-way switches are in the path from B to the oven, while A goes straight to the oven coil.
Step 2 — Decide the live wire (part a1).
Switches must be in the live wire, so that when the oven is switched off from either place it is completely cut off from the high potential. So B should be the live wire. If A were live, the oven coil would stay at 220 V even when switched off, and touching it could give a shock.
Step 3 — Check the fuse (part a2).
The fuse is in the wire from the oven's body to the earth C. On an overload the excess current flows through the live and neutral wires (B and A), not through the earth wire, so the fuse does not melt and the circuit is not broken: it will not serve its purpose. The fuse must be in the live wire B, before the switches, with the earth wire going straight to the oven's metal body.

Step 4 — Explain the rating (part b).
When the bulb is connected to a 220 V supply it consumes electrical energy at the rate of 600 J every second (power 600 W) and gives its normal light. From the rating we can also find its current and resistance.
I=VP=220600≈2.73 A
R=PV2=6002202≈80.67 Ω
Watch out: A fuse in the EARTH wire never sees the overload current.
Therefore, (a)(1) B should be the live wire, because the switches are in its path; (a)(2) no, the fuse is in the earth wire, which does not carry the overload current; (b) the bulb uses 600 W (600 J each second) when connected to a 220 V supply.