A fuse is rated 5 A. Can it be used with a geyser rated 1540 W, 220 V. Write Yes or No. Give supporting calculations to justify your answer.
Previous Year Questions · Question 16 of 27
A fuse is rated 5 A.
Solution:
Concept: A rating such as '1540 W, 220 V' means the appliance uses that power when connected to that voltage. Its normal working current is I = P ÷ V, and a fuse used with it must be rated a little above this current, or it would melt as soon as the appliance is switched on.
Given: Fuse 5 A; geyser 1540 W, 220 V.
Step 1 — Find the current drawn.
The geyser draws a current I = P ÷ V.
Step 2 — Compare with the fuse.
The geyser draws 7 A, more than the fuse rating of 5 A, so the fuse would melt as soon as the geyser is switched on. A fuse of a little higher rating, such as 8 A, should be used.
Watch out: A fuse must be rated ABOVE the working current, not below it.
Therefore, no: the geyser draws 7 A, which is more than 5 A.