A steel column in a building is 3.0 m tall and has a cross-sectional area of 2.0 × 10^ -2 m² .

Question 381 markMCQMedium

A steel column in a building is 3.0 m3.0\ \text{m} tall and has a cross-sectional area of 2.0×10−2 m22.0 \times 10^{-2}\ \text{m}^2. It carries a compressive load of 6.0×105 N6.0 \times 10^{5}\ \text{N} from the floors above, well within its elastic limit. Young's modulus of steel is 2.0×1011 N m−22.0 \times 10^{11}\ \text{N m}^{-2}. (Hypothetical data.) The elastic energy stored in the compressed column is about

Select your answer
  • (A) 135 J135\ \text{J}

    Correct answer
  • (B) 270 J270\ \text{J}

  • (C) 1.35×105 J1.35 \times 10^{5}\ \text{J}

  • (D) 45 J45\ \text{J}