Possible reasons
- The switch is not really closed. In Fig. 3.19 the safety pin is not touching the second drawing pin. If the safety pin does not press on both drawing pins, a gap remains and the circuit stays open.
- The cell is used up. A cell that can no longer give electrical energy cannot make current flow.
- The lamp is fused. Its filament may be broken, so current cannot pass through the lamp.
- A loose connection. A wire end may not be touching the cell terminal, a screw of the lamp holder or a drawing pin, or the lamp may be loose in its holder.
- Covering not removed. The plastic covering at a wire end may not have been removed, so only an insulator touches the terminal.
- A broken wire. The metal inside a wire may be broken even though its plastic covering looks fine.
- Rust or dirt on the drawing pins, the safety pin or the cell terminals may stop the metal parts from touching properly.
How to find the fault
Check one part at a time, changing only that part and keeping the rest of the circuit the same:
- Press the safety pin firmly onto the second drawing pin. If the lamp now glows, the switch was the problem.
- Check every joint: tighten loose ends, make sure the bare metal of each wire touches its terminal, and push the lamp firmly into its holder.
- Take the switch out and touch its two wires directly together. If the lamp glows now, the switch is faulty.
- Put a new cell, or one that works in another circuit, in place of the old cell. If the lamp now glows, the old cell was used up.
- Put a lamp that glows in another circuit in place of the old lamp, or look at its filament. If the new lamp glows, the old one was fused.
- Test each wire with a working conduction tester (a cell, a lamp and wires). If the tester lamp does not glow through a wire, that wire is broken.
The first change that makes the lamp glow shows the fault.