Describe the procedure to measure the diameter of a wire with the help of a screw gauge.
Measurements and Experimentation · Question 98 of 151
Describe the procedure to measure the diameter of a wire with the help of a screw gauge.
Solution:
Concept: A screw-gauge reading is main scale reading + (circular-scale division on the base line) × L.C. The main scale reading is the last millimetre (or half-millimetre) mark visible on the sleeve beside the edge of the thimble. Correct reading = observed reading − zero error, where the zero error is used with its own sign. So a positive zero error is subtracted, and a negative zero error ends up being added.
Step 1 — Find the least count and the zero error.
Find the pitch and the number of circular divisions, and work out L.C. as pitch ÷ N. Then bring the flat end B against the stud A using the ratchet, and find the zero error with its sign.
Step 2 — Place the wire.
Turn the ratchet back to open a gap between A and B, put the wire in the gap, and turn the ratchet forward until the wire is held gently between A and B.
Step 3 — Take the main scale reading.
Note the last millimetre mark visible on the sleeve beside the edge of the thimble; this is the main scale reading a.
Step 4 — Take the circular scale reading.
Note the circular division p in line with the base line; the circular scale reading b is p × L.C.
Step 5 — Find the observed diameter.
Add the two readings: the observed diameter is a + b.
Step 6 — Repeat.
Turn the wire through 90° in the same place and read again, since a wire may not be perfectly round. Take readings at two more places along the wire, and find the mean observed diameter.
Step 7 — Correct for zero error.
Subtract the zero error, with its sign, from the mean observed diameter.
Watch out: Turn the screw in one direction only while taking readings, to avoid backlash error.
Therefore, the diameter of the wire is main scale reading + p × L.C., averaged over several readings and corrected for the zero error.