“Wheatstone bridge method is not preferred for the accurate measurement of very low and very high resistances.” Why?
Direct Current Circuits · Question 61 of 126
“Wheatstone bridge method is not preferred for the accurate measurement of very low and very high resistances.” Why?
Solution:
Key idea: A Wheatstone bridge is accurate only when the four arm resistances are of similar size and the galvanometer shows a clear deflection for a small departure from balance.
Step 1 — Explain the problem with very low resistances.
For a very low resistance (a small fraction of an ohm), the resistances of the connecting wires, the contacts and the end connections are comparable with the resistance being measured. They add to it in the arm and cannot be separated from it, so the value found has a large error.
Step 2 — Explain the problem with very high resistances.
For a very high resistance (many megohms), the currents in the arms are extremely small. Near balance the galvanometer current is too small to give a visible deflection, so the null point cannot be located precisely. Small leakage currents over the surfaces of the insulation also become comparable with the arm currents.
Step 3 — Conclude where the bridge works well.
The bridge is therefore best for resistances of moderate value, where lead resistances are negligible and the galvanometer is sensitive enough near balance.
Therefore, the Wheatstone bridge is not used for very low resistances because lead and contact resistances cause large errors, nor for very high resistances because the galvanometer becomes too insensitive near balance (and leakage currents interfere).