The variation of potential difference V with length in case of two potentiometer x and y is as shown in the given figure. Which one of these two will you prefer for comparing emfs of two cells and why?

Confirming your payment
Sign up now and get 250 free tokens.
Direct Current Circuits · Question 22 of 126
The variation of potential difference V with length in case of two potentiometer x and y is as shown in the given figure. Which one of these two will you prefer for comparing emfs of two cells and why?

Solution:
Key idea: For a potentiometer the graph of against is a straight line through the origin, and its slope is the potential gradient . The smaller the gradient, the longer the balancing length for a given emf, and the more sensitive the potentiometer.
Step 1 — Compare the slopes.
Line x is steeper than line y, so potentiometer x has the larger potential gradient and potentiometer y the smaller one.
Step 2 — See how the gradient affects a measurement.
A cell of emf balances at a length that is inversely proportional to the gradient.
With the smaller gradient of y, the balancing length is longer. The same small error in reading the length is then a smaller fraction of it, and a small change in emf moves the balance point further, so y is more sensitive and more accurate.
Step 3 — Choose the potentiometer.
For comparing emfs we want the more sensitive instrument, which is y.
Therefore, potentiometer y is preferred, because its smaller potential gradient (smaller slope) makes it more sensitive and gives longer, more accurate balancing lengths.