The potentiometer is best for measuring voltage as
Direct Current Circuits · Question 1 of 126
The potentiometer is best for measuring voltage as
- Correct answer
(A) it has sensitive galvanometer and gives null deflection
(B) it has wire of high resistance
(C) it measures p.d. in closed circuit
(D) it measures p.d. in open circuit
Answer: (A) it has sensitive galvanometer and gives null deflection
Key idea: A potentiometer is a null (balance) instrument. At the balance point its galvanometer shows no deflection, so no current is drawn from the cell or circuit being measured.
Step 1 — Recall how a voltmeter measures.
A voltmeter is connected across the source and must draw a small current to deflect. The source then loses a p.d. inside itself, so the voltmeter reads less than the true value.
Step 2 — Recall how a potentiometer measures.
The unknown p.d. is balanced against the fall of potential along the potentiometer wire. At balance the sensitive galvanometer shows zero deflection, so no current flows from the source and nothing is lost inside it.
Step 3 — Pick the reason.
The accuracy therefore comes from the null deflection read on a sensitive galvanometer, which is what option (A) states.
Why the other options are wrong:
- (B) is wrong: The wire is made of a high-resistivity alloy, but its total resistance is only a few ohms; the accuracy comes from the null method, not from a high wire resistance.
- (C) is wrong: Measuring while drawing current from the circuit is exactly what a voltmeter does, and that is the cause of its error; a potentiometer draws no current at balance.
- (D) is wrong: It is partly true, since at balance the source gives no current and so behaves as on open circuit; but this follows from the null deflection in (A), which is the reason the question asks for.
Note: The open-circuit option describes a result of the same zero-current balance. The null-deflection option is kept as the key because it names the cause.
Therefore, a potentiometer is best for measuring voltage because it uses a sensitive galvanometer and a null deflection: option (A).