The coil used for making standard resistance, like manganin, is double folded and is wound over non-conducting frame. Why?
Electric Current - Ohm's Law · Question 57 of 128
The coil used for making standard resistance, like manganin, is double folded and is wound over non-conducting frame.
Solution:
Key idea: A standard resistance must act as a pure, steady resistance: it should have no self-inductance and no current should leak out of the coil.
Step 1 — Explain the double folding.
The wire is folded back on itself and the two halves are wound side by side (bifilar winding). The current flows in opposite directions in the two halves, so their magnetic fields cancel and the coil has almost no self-inductance. No induced e.m.f. then appears when the current is switched on or off or changes.
Step 2 — Explain the non-conducting frame.
The coil is wound on an insulating frame, so no current can leak from one turn to another or to the support. All the current goes through the full length of the wire, and the resistance keeps its stated value.
Therefore, double folding makes the coil non-inductive, and the non-conducting frame prevents leakage of current from the coil.