Draw a diagram showing the variation of intensity of X-rays emitted with wavelength with different accelerating potentials applied to the tube.
X-Rays · Question 28 of 50
Draw a diagram showing the variation of intensity of X-rays emitted with wavelength with different accelerating…
Solution:
Concept: The continuous X-ray spectrum starts at a shortest wavelength , about with in volts, so becomes shorter as the accelerating potential is raised.
Step 1 — Draw the graph. The figure shows the intensity of the continuous X-rays against wavelength for 10, 15, 20 and 25 kV (the characteristic lines are not shown).

Step 2 — Read off the cut-off wavelengths. The values of for the four voltages are:
Step 3 — Describe the features. Each curve starts sharply at its own , rises to a maximum and then falls slowly. As the voltage increases, and the peak both move to shorter wavelengths, and the intensity at every wavelength increases.
Therefore, the graphs show that a higher accelerating potential gives a shorter cut-off wavelength , a peak at a shorter wavelength and a greater intensity.