Why the size of the needle of a syringe controls flow rate better than the thumb pressure exerted by a doctor while administering an injection?
Fluid Pressure and Viscosity · Question 17 of 78
Why the size of the needle of a syringe controls flow rate better than the thumb pressure exerted by a doctor while…
Solution:
Concept: Poiseuille's formula gives the volume of liquid flowing per second through a narrow tube of radius and length under a pressure difference :
Step 1 — Compare the two dependences. The rate of flow is proportional to but only to the first power of . Halving the radius of the needle reduces the flow 16 times, while halving the thumb pressure reduces it only 2 times.
Step 2 — Draw the conclusion. So a small change in the bore of the needle changes the flow far more than the doctor can change it by pressing harder or more gently.
Note: the book's hint explains this through the high pressure at the small tip of the needle; the deciding factor is the fourth-power dependence of the flow on the radius in Poiseuille's formula.
Therefore, the size of the needle controls the flow rate better, because the rate depends on the fourth power of the radius of the needle but only on the first power of the pressure.