is
Environmental Chemistry · Question 60 of 122
BOD₅ is
(A) waste decomposed in 5 days
- Correct answer
(B) oxygen used in 5 days
(C) microorganisms killed in 5 days
(D) dissolved oxygen left after 5 days
Answer: (B) oxygen used in 5 days
Key idea: Biochemical oxygen demand (BOD) is the amount of oxygen used by bacteria to break down the organic matter in a sample of water, measured over 5 days at 20 °C. Clean water has a BOD below 5 ppm; highly polluted water has a BOD of 17 ppm or more.
Step 1 — Recall how BOD is measured. The sample is saturated with oxygen and its dissolved oxygen is measured; it is then kept in the dark at 20 °C for 5 days and the dissolved oxygen is measured again.
Step 2 — Define BOD₅. The difference between the two readings is the oxygen used by microorganisms in 5 days, which is the BOD₅.
Why the other options are wrong:
- (A) BOD₅ is expressed as the mass of oxygen used, not as the amount of waste decomposed.
- (C) The test measures oxygen used by living microorganisms; it does not count microorganisms killed.
- (D) The dissolved oxygen left after 5 days is only the second reading; BOD₅ is the oxygen used up, found by subtracting it from the first reading.
Therefore, BOD₅ is the oxygen used by microorganisms in 5 days.