What is the difference between BOD and COD? Which is better and Why?
Environmental Chemistry · Question 115 of 122
What is the difference between BOD and COD? Which is better and Why?
Solution:
Key idea: Both BOD and COD measure how much oxygen would be needed to oxidise the pollutants in water, but BOD uses micro-organisms (so it counts only biodegradable matter, and takes days), while COD uses a strong chemical oxidising agent, acidified potassium dichromate (so it counts almost all oxidisable matter, and takes a few hours).
Step 1 — Define BOD. Biochemical Oxygen Demand is the amount of oxygen used by micro-organisms in decomposing the organic matter in a water sample. The sample is saturated with oxygen, kept in the dark at 20 °C for 5 days, and the fall in dissolved oxygen is measured; the result is given in ppm (mg L⁻¹).
Step 2 — Define COD. Chemical Oxygen Demand is the amount of oxygen (in ppm) equivalent to the acidified potassium dichromate used up in oxidising the pollutants in a water sample. A known excess of dichromate is boiled with the sample; the dichromate left over is found by titration with Mohr's salt, and the dichromate used is converted to oxygen.
Step 3 — Convert dichromate to oxygen. The symbol [O] in the equation above is only textbook shorthand for the oxidising power of dichromate. What really happens is that each dichromate ion takes up six electrons.
An oxygen molecule takes up four electrons when it oxidises a pollutant, so six electrons are worth one and a half moles of (three moles of oxygen atoms).
The mass of oxygen equal to one mole of dichromate is therefore found as follows.
So every mole of dichromate used corresponds to 48 g of oxygen demand.
Step 4 — Compare them. The table below sets the two measures side by side, point by point.
| Point | BOD | COD |
|---|---|---|
| Oxidising agent | micro-organisms (bacteria) and dissolved oxygen | acidified (chemical) |
| What it measures | only biodegradable organic matter | almost all organic and oxidisable inorganic matter, biodegradable or not |
| Time taken | 5 days | about 2–3 hours |
| Effect of poisons | toxic wastes kill the microbes and give a falsely low value | not affected by toxic substances |
| Usual size | smaller | larger (COD is usually greater than BOD) |
Step 5 — Decide which is better. COD is generally the better measure of pollution. It is quick (hours instead of days), its results are more reproducible, it is not upset by toxic industrial wastes, and it includes the non-biodegradable pollutants that BOD misses. BOD is still useful because it shows how fast the biodegradable waste will actually use up the dissolved oxygen of a river, so the two are often used together (the ratio BOD/COD shows how biodegradable a waste is).
Therefore, BOD is the oxygen used by micro-organisms in 5 days to decompose only the biodegradable organic matter, while COD is the oxygen equivalent of acidified dichromate used to oxidise almost all oxidisable matter in a few hours; COD is generally better because it is faster, more reproducible, unaffected by toxic wastes and covers non-biodegradable pollutants too.