In the transmission of power the voltage of power generated at the generating station is stepped up from 11 kV to 132 kV before it is transmitted. Why?
Household Circuits · Question 17 of 73
In the transmission of power the voltage of power generated at the generating station is stepped up from 11 kV to 132…
Solution:
Concept: For a given power P = VI, the current is I = P ÷ V, so a higher voltage means a smaller current. The heat wasted in line wires of resistance R in time t is H = I²Rt, so a smaller current wastes much less energy as heat.
Step 1 — Find how the current changes.
The power P sent out is the same at both voltages. Since I = P ÷ V, the current is inversely proportional to the voltage, so the new current is 11/132 of the old one.
Step 2 — Find how the heat loss changes.
The heat produced in line wires of resistance R in time t is H = I²Rt. With the same wires and time, the heat is proportional to I², so it becomes (1/12)² of the old value.

Step 3 — State the result.
So the step-up greatly reduces the loss of energy as heat during transmission. A smaller current also allows thinner, cheaper line wires.
Watch out: The loss falls with the SQUARE of the current, so a current 12 times smaller wastes 144 times less heat.
Therefore, the voltage is stepped up to 132 kV so that the current in the line wires becomes small (1/12) and the loss of energy as heat in them is greatly reduced (to 1/144).