Solution:
Concept: A transformer has two coils of insulated copper wire, the primary and the secondary, wound on a closed core of laminated soft iron. It works on mutual induction and only with a.c. A step-up transformer has more turns in the secondary than in the primary (Ns > Np), so it raises the voltage and lowers the current. A step-down transformer has fewer turns in the secondary (Ns < Np), so it lowers the voltage and raises the current.
(a)
Step 1 — State the material and structure of the core.
The core is made of soft iron. It is laminated: it is built up from thin sheets of soft iron insulated from one another by varnish, arranged as a closed rectangular frame. The soft iron is easily magnetised and demagnetised, and the lamination reduces the eddy-current loss.
(b)
Step 2 — Complete the diagram.
A primary coil of many turns of insulated copper wire is wound on the left limb and joined to the input (220 V a.c. mains). A secondary coil of fewer turns is wound on the right limb and joined to the output (44 V a.c.).

The completed figure labels the laminated soft iron core, the primary (many turns, 220 V a.c.) and the secondary (few turns, 44 V a.c.).
Step 3 — Find the turns ratio.
The turns ratio equals the voltage ratio, so the secondary has one-fifth as many turns as the primary.
NpNs=22044=51
(c)
Step 4 — Name the transformer.
The output voltage (44 V) is less than the input voltage (220 V), so it is a step-down transformer.
Watch out: The coil joined to the mains is the primary, even though it has more turns here.
Therefore, (a) the core is a closed frame of thin laminated soft iron sheets, (b) a primary coil of many turns joined to the 220 V input and a secondary coil of one-fifth as many turns joined to the 44 V output complete the diagram, and (c) the transformer is step down.