Competency: Analysis & Evaluation
During a heart procedure guided by moving X-ray images (fluoroscopy), a cardiologist stands from the place where the X-ray beam enters the patient. X-rays scattered by the patient's body reach the cardiologist. At these would give the cardiologist's body a radiation dose at a rate of per hour if no protection were worn. (The millisievert, mSv, measures how much harm a dose of radiation can do.) The cardiologist's lead apron lets through of this radiation. The X-ray beam is on for minutes in each procedure, and the cardiologist's yearly dose must stay under . Treat the patient as a point source of the scattered X-rays. (Hypothetical data.)
(a) Find the dose the cardiologist would receive in one procedure without the apron, and the dose received with it.
(b) How many procedures can the cardiologist carry out in a year, wearing the apron, without going over the yearly limit?
(c) During of the minutes the cardiologist need not be close to the patient, and so steps back to . Find the new dose per procedure (wearing the apron), and the percentage by which this lowers the dose.