Confirming your payment

Skip to content

Sign up now and get .

Competency-Based Questions (CBQ) · Question 40 of 40

Competency: Analysis & Evaluation Each year a hospital physicist checks the X-ray beam of a radiography unit run at 80…

Question 404 marksHard

Competency: Analysis & Evaluation

Each year a hospital physicist checks the X-ray beam of a radiography unit run at 8080 kV. Sheets of aluminium are placed one by one across the beam, and a detector behind them measures the intensity. The table gives it as a percentage of the intensity with no aluminium. The thickness of aluminium that halves the intensity is called the half-value thickness. The larger it is, the more penetrating (harder) the beam. The hospital's rule is that at 8080 kV the first half-value thickness must be at least 2.52.5 mm. (Hypothetical data.)

Aluminium thickness (mm)001.01.02.02.03.03.04.04.05.05.06.06.07.07.0
Intensity (%)10010077.277.261.461.450.050.041.441.434.734.729.329.325.025.0

(a) Use the table to find the first half-value thickness, and the extra thickness of aluminium that halves the intensity again (the second half-value thickness).

(b) Use the data to explain why the second half-value thickness is larger than the first.

(c) Does the beam pass the hospital's rule? A trainee suggests that, if a beam ever fails the rule, doubling the tube current will make it more penetrating. Evaluate this suggestion.