Competency: Analysis & Evaluation
Three designs P, Q and R of an analogue voltmeter use the same needle and the same control spring but different amounts of damping. The same steady voltage is applied to each. Design P's needle swings past the final reading and oscillates several times before settling; design Q's needle moves to the final reading without overshooting and settles there soonest; design R's needle creeps slowly towards the final reading and takes much longer to settle. Which statement is correct?