Competency: Analysis Overhead power lines often use a steel-cored aluminium conductor.

Question 393 marksHard

Competency: Analysis

Overhead power lines often use a steel-cored aluminium conductor. In one such conductor, a core of steel wires with a total area of cross-section of 50 mm250\ \text{mm}^2 is surrounded by aluminium strands of total area 300 mm2300\ \text{mm}^2. The steel and aluminium are clamped together at the ends of each span, so they always have the same length and stretch together. For the steel, Y=2.0×1011 PaY = 2.0 \times 10^{11}\ \text{Pa}; for the aluminium, Y=7.0×1010 PaY = 7.0 \times 10^{10}\ \text{Pa}. In one span the conductor is pulled with a tension of 20 kN20\ \text{kN}. (Hypothetical data.)

(a) Find the strain in the conductor.

(b) Find the stress in the steel and in the aluminium, and the fraction of the tension carried by the steel core.

(c) The aluminium may be stressed safely up to 6.0×107 Pa6.0 \times 10^{7}\ \text{Pa} and the steel up to 4.0×108 Pa4.0 \times 10^{8}\ \text{Pa}. Find the greatest tension this conductor may carry, and compare it with the greatest tension of an all-aluminium conductor of the same total area, 350 mm2350\ \text{mm}^2.