(a) The n-side is full of free electrons (the majority carriers). An injected hole moving into it soon meets an electron and recombines, so the injected holes disappear within a short distance of the junction. The hole concentration is therefore high at the junction and falls with distance, and this gradient keeps the diffusion going. As long as the battery maintains the forward bias, it keeps supplying holes at the p-side and electrons at the n-side, so the gradient, and the diffusion current, persist. The concentrations never become equal.
(b) Under forward bias the hole concentration on the n-side is highest at the edge of the junction and falls towards the small equilibrium minority value (ni2/ND) as the injected holes recombine. In the unbiased junction there is no injection, and the hole concentration on the n-side stays at that equilibrium value.

(c) Increasing V lowers the barrier V0−V further. Many more holes on the p-side now have enough energy to cross it, so more holes are injected each second and the hole concentration at the n-side edge of the junction rises. They still recombine within a short distance, so the concentration falls away over about the same distance as before, but from a higher starting value: the gradient becomes steeper. A steeper gradient means a larger diffusion current, so the forward current increases, and because the number of carriers able to cross grows so rapidly as the barrier falls, the current rises sharply once the threshold is passed.