Many filament lamps are filled with argon at nearly atmospheric pressure instead of being evacuated. The hot tungsten filament slowly loses atoms by evaporation. Using the idea of mean free path, explain how the argon helps the filament last longer and keeps the glass clear.
Competency-Based Questions (CBQ) · Question 40 of 80
Many filament lamps are filled with argon at nearly atmospheric pressure instead of being evacuated.
Question 402 marksMedium
In argon near the number density is about , so the mean free path is only about , far smaller than the size of the bulb. A tungsten atom leaving the filament therefore collides with argon atoms within a tiny fraction of a millimetre, and many such atoms are knocked straight back onto the filament, so the filament wears away much more slowly. In an evacuated bulb is so small that is larger than the bulb itself; each evaporated atom flies in a straight line to the glass, sticks there and blackens it, while the filament thins quickly. What matters is how compares with the size of the vessel.