(a) The highest possible efficiency is that of a Carnot engine between the same two temperatures:
ηmax=1−T1T2=1−773300=0.612=61.2 %
(b) Efficiency is useful work out divided by heat in, so
heat input rate=0.35500 MW=1.43×103 MW
Energy is conserved, so whatever is not delivered as work must be rejected as heat:
heat to river=1.43×103−500=929 MW≈9.3×102 MW
(c) Each second 100 m3, i.e. 1.0×105 kg, of water receives 9.29×108 J:
ΔT=1.0×105×41869.29×108=2.2 K
A rise of about 2 K all along a river can harm fish and plants, which is why such stations need large rivers or cooling towers.
(d) The Carnot value applies only to a reversible engine. A real station is irreversible:
- Heat flows across large temperature differences, for example from the furnace flame (well above 773 K) to the boiler water, and from the exhaust steam to the cooling water; such heat flow is not quasi-static and cannot be reversed.
- There are dissipative effects: friction in the turbines and bearings, turbulence in the steam, and electrical losses in the generator, all of which turn useful energy into internal energy.
- Some heat escapes up the chimney with the hot flue gases without ever reaching the steam.
So even the best real station falls well short of 61 %; the Carnot value is an upper limit that no real engine can reach.