(a) For a solid, αV=3αl, so the linear coefficient of ordinary glass is
αl=32.5×10−5=8.33×10−6 K−1
The inner diameter grows as if the opening were filled with glass:
Δd=dαlΔT=0.020×8.33×10−6×40=6.7×10−6 m=6.7 μm
(b) The stopper's diameter then grows by 0.020×8.33×10−6×10=1.7 μm, so the clearance gained is
0.020×8.33×10−6×(40−10)=5.0 μm
A few micrometres is enough to free a tight ground-glass joint, but the gain disappears as the temperatures even out.
(c) Neck and stopper are the same glass, with the same αl. If both reach the same temperature, both grow by the same fraction and no clearance is gained; this is what happens in an oven. The trick works only while the neck is hotter than the stopper. Glass is a poor conductor (K≈0.8 W m−1 K−1), so the heat takes some time to pass inward to the stopper; pouring hot water on the outside of the neck and pulling at once uses this delay.