Option (A) is correct.
Explanation: Both scales are linear in the same thermometric property, so the fraction of the way from the ice point to the steam point is the same on both:
140−(−10)X−(−10)=100−0tC−0⇒X=1.5tC−10
The readings agree when X=tC:
tC=1.5tC−10⇒tC=20 ∘C
For a change, the constant −10 drops out: ΔX=1.5ΔtC. A rise of 6.0 X-degrees is therefore a rise of 6.0/1.5=4.0 ∘C, and a Celsius degree is the same size as a kelvin, so the rise is 4.0 K. (Check: at 20 ∘C, X=1.5×20−10=20.)
(B) is wrong: it writes the ice point as +10, so that X=1.5tC+10, which gives −20 ∘C; the ice-point reading is −10.
(C) is wrong: the agreement temperature is right, but it multiplies by 1.5 instead of dividing; each X-degree is smaller than a Celsius degree, since 150 X-degrees span 100 ∘C.
(D) is wrong: it takes the span between the fixed points as 140−10=130 X-degrees instead of 140−(−10)=150.