(a) The resistance becomes extremely small — very close to zero.
Normally the current has to pass through the appliance, which is what provides the resistance in the circuit. When live touches neutral the current gets a path made of nothing but copper wire, which has almost no resistance, and it bypasses the appliance altogether. This is a short circuit.
(b) From Ohm's law,
I=RV
The supply voltage V is unchanged at 220 V, but R has collapsed to nearly zero — so the current becomes enormous. Where the appliance might normally draw a few amperes, a short circuit can draw hundreds.
That current passes through the household wiring, and by the heating effect,
H=I2Rt
the heat produced rises with the square of the current. The wires themselves get hot enough to melt their insulation and set fire to whatever they are touching.
(c) A fuse is a short piece of thin wire of low melting point, connected in series in the live wire. The whole circuit current flows through it. When that current becomes dangerously large, the fuse wire is the first thing to get hot enough to melt — and when it melts it breaks the circuit, so the current stops before the household wiring has time to overheat.
Why the rating must be lower than the wiring can take. The fuse is not protecting the appliance; it is protecting the wires in the walls. If a 5 A circuit were fitted with a 15 A fuse, a fault drawing 12 A would not melt the fuse at all — and the wiring, rated for 5 A, would sit there carrying more than twice its safe current until something caught fire. A fuse only works if it is the weakest point in the circuit by design.

When the resistance collapses, the current surges.