Opening your dashboard
Class 12 Physics Chapter 25 X-Rays: Previous Year Questions
4 questions on Chapter 25, each solved step by step. Class 12 Physics, ICSE 2026-27.
4 questions with solutions
1–2 marks · Mixed difficulty
- 11 mark
Question 1
State Moseley's law.
Solve with AIWritten solution
Solution:
Key idea: Each element gives characteristic X-ray lines (K, L, …) whose frequencies depend on its atomic number . Moseley found a simple law linking the two.
Step 1 — State the law in words.
The square root of the frequency of a given characteristic X-ray line (for example the line) of an element is directly proportional to , where is the atomic number of the element.
Step 2 — Write it as an equation.
Here and are constants for that line ( for the line).
Therefore, Moseley's law: the square root of the frequency of a characteristic X-ray line is directly proportional to (Z − b), that is √ν = a(Z − b), where Z is the atomic number and a, b are constants.
- 22 marks
Question 2
Using the constants given on page 8 of this Paper, find the minimum wavelength of the emitted X rays, when an X ray tube is operated at .
Solve with AIWritten solution
Solution:
Key idea: The shortest wavelength (cut-off wavelength) of X-rays is emitted when an electron accelerated through the tube voltage gives all its kinetic energy to a single X-ray photon (the Duane–Hunt law).
Step 1 — Write the data with the paper's constants.
We use , and , with the tube voltage in volts.
Step 2 — Find the energy gained by each electron.
Each electron of charge falls through the potential difference , so it gains energy .
Step 3 — Rearrange for the minimum wavelength.
We make the subject of the Duane–Hunt relation.
Step 4 — Substitute the values.
We put in and the electron energy from Step 2.
The exact value with these constants is , about .
Therefore, the minimum wavelength of the emitted X-rays is about 2.48 × 10⁻¹¹ m (0.25 Å).
- 32 marks
Question 3
State the effect of the following changes on the X-rays emitted by Coolidge X-ray tube:
(i) High voltage between cathode and anode is increased.
(ii) Filament temperature is increased.
Solve with AIWritten solution
Solution:
Key idea: In a Coolidge tube the high voltage decides the energy of the electrons striking the target, and so the quality (penetrating power) of the X-rays. The filament temperature decides how many electrons are emitted, and so the intensity of the X-rays.
Step 1 — Part (i): find the effect on the energy of the X-rays.
A higher voltage gives each electron more kinetic energy . The minimum wavelength falls, because , and the X-ray photons have more energy on average.
Step 2 — Part (i): state the result.
The X-rays become harder (more penetrating), so their quality improves. In the ISC treatment the number of X-ray photons is set by the tube current, so the intensity is taken as unchanged.
Step 3 — Part (ii): find the effect on the number of electrons.
A hotter filament emits more electrons per second by thermionic emission, so the tube current increases.
Step 4 — Part (ii): state the result.
More electrons strike the target each second, so more X-ray photons are produced and the intensity of the X-rays increases. The voltage is unchanged, so the minimum wavelength and the penetrating power (quality) stay the same.
Note: In practice the total X-ray power also rises when the voltage is raised (roughly as the square of the voltage, Kramers' rule), because each electron brings more energy and also turns a larger share of it into X-rays.
Therefore, (i) increasing the high voltage makes the X-rays more penetrating (harder, shorter minimum wavelength); (ii) increasing the filament temperature increases the intensity of the X-rays without changing their quality.
- 42 marks
Question 4
(i) Find maximum frequency of X-rays produced by an X-ray tube operating at a tube potential of .
(ii) State any one difference between characteristic X-rays and continuous X-rays.
Solve with AIWritten solution
Solution:
Key idea: An electron accelerated through a potential difference gains energy . The highest-frequency X-ray photon is produced when all of this energy goes into one photon, so .
Step 1 — Part (i): write the data with the paper's constants.
We use and , with the tube potential in volts.
Step 2 — Part (i): find the maximum frequency.
We rearrange for and substitute.
Step 3 — Part (ii): give one difference.
Continuous X-rays contain all wavelengths above a minimum wavelength . That minimum depends only on the tube voltage, not on the target. Characteristic X-rays appear as sharp lines at a few definite wavelengths that depend only on the element of the target (they come from electron jumps between inner shells of the target atoms), not on the voltage.
Therefore, (i) the maximum frequency of the X-rays is 1.6 × 10¹⁹ Hz; (ii) continuous X-rays have all wavelengths above a cut-off set by the tube voltage, whereas characteristic X-rays have a few sharp wavelengths that depend on the target element.