  1. 1

    Question 1

    State Moseley's law.

    EasyAsked 2015
    1 mark
    Solve with AI
    Written solution

    Solution:

    Key idea: Each element gives characteristic X-ray lines (K, L, …) whose frequencies depend on its atomic number ZZ. Moseley found a simple law linking the two.

    Step 1 — State the law in words.

    The square root of the frequency ν\nu of a given characteristic X-ray line (for example the KαK_\alpha line) of an element is directly proportional to (Z−b)(Z - b), where ZZ is the atomic number of the element.

    Step 2 — Write it as an equation.

    Here aa and bb are constants for that line (b≈1b \approx 1 for the KαK_\alpha line).

    ν=a(Z−b)\sqrt{\nu} = a(Z - b)

    Therefore, Moseley's law: the square root of the frequency of a characteristic X-ray line is directly proportional to (Z − b), that is √ν = a(Z − b), where Z is the atomic number and a, b are constants.

  2. 2

    Question 2

    Using the constants given on page 8 of this Paper, find the minimum wavelength of the emitted X rays, when an X ray tube is operated at 50 kV50\ \mathrm{kV}.

    MediumAsked 2015
    2 marks
    Solve with AI
    Written solution

    Solution:

    Key idea: The shortest wavelength (cut-off wavelength) of X-rays is emitted when an electron accelerated through the tube voltage VV gives all its kinetic energy eVeV to a single X-ray photon (the Duane–Hunt law).

    eV=hcλmin⁡eV = \frac{hc}{\lambda_{\min}}

    Step 1 — Write the data with the paper's constants.

    We use h=6.6×10−34 J sh = 6.6 \times 10^{-34}\ \text{J s}, c=3.0×108 m s−1c = 3.0 \times 10^{8}\ \text{m s}^{-1} and e=1.6×10−19 Ce = 1.6 \times 10^{-19}\ \text{C}, with the tube voltage in volts.

    V=50 kVV = 50\ \text{kV}

    V=5.0×104 VV = 5.0 \times 10^{4}\ \text{V}

    Step 2 — Find the energy gained by each electron.

    Each electron of charge ee falls through the potential difference VV, so it gains energy eVeV.

    eV=1.6×10−19×5.0×104eV = 1.6 \times 10^{-19} \times 5.0 \times 10^{4}

    eV=8.0×10−15 JeV = 8.0 \times 10^{-15}\ \text{J}

    Step 3 — Rearrange for the minimum wavelength.

    We make λmin⁡\lambda_{\min} the subject of the Duane–Hunt relation.

    λmin⁡=hceV\lambda_{\min} = \frac{hc}{eV}

    Step 4 — Substitute the values.

    We put in hchc and the electron energy from Step 2.

    λmin⁡=6.6×10−34×3.0×1088.0×10−15\lambda_{\min} = \frac{6.6 \times 10^{-34} \times 3.0 \times 10^{8}}{8.0 \times 10^{-15}}

    λmin⁡=1.98×10−258.0×10−15\lambda_{\min} = \frac{1.98 \times 10^{-25}}{8.0 \times 10^{-15}}

    λmin⁡≈2.48×10−11 m\lambda_{\min} \approx 2.48 \times 10^{-11}\ \text{m}

    The exact value with these constants is 2.475×10−11 m2.475 \times 10^{-11}\ \text{m}, about 0.25 A˚0.25\ \text{Å}.

    Therefore, the minimum wavelength of the emitted X-rays is about 2.48 × 10⁻¹¹ m (0.25 Å).

  3. 3

    Question 3

    State the effect of the following changes on the X-rays emitted by Coolidge X-ray tube:

    (i) High voltage between cathode and anode is increased.

    (ii) Filament temperature is increased.

    MediumAsked 2016
    2 marks
    Solve with AI
    Written solution

    Solution:

    Key idea: In a Coolidge tube the high voltage VV decides the energy of the electrons striking the target, and so the quality (penetrating power) of the X-rays. The filament temperature decides how many electrons are emitted, and so the intensity of the X-rays.

    Step 1 — Part (i): find the effect on the energy of the X-rays.

    A higher voltage gives each electron more kinetic energy eVeV. The minimum wavelength falls, because λmin⁡=hceV\lambda_{\min} = \dfrac{hc}{eV}, and the X-ray photons have more energy on average.

    Step 2 — Part (i): state the result.

    The X-rays become harder (more penetrating), so their quality improves. In the ISC treatment the number of X-ray photons is set by the tube current, so the intensity is taken as unchanged.

    Step 3 — Part (ii): find the effect on the number of electrons.

    A hotter filament emits more electrons per second by thermionic emission, so the tube current increases.

    Step 4 — Part (ii): state the result.

    More electrons strike the target each second, so more X-ray photons are produced and the intensity of the X-rays increases. The voltage is unchanged, so the minimum wavelength and the penetrating power (quality) stay the same.

    Note: In practice the total X-ray power also rises when the voltage is raised (roughly as the square of the voltage, Kramers' rule), because each electron brings more energy and also turns a larger share of it into X-rays.

    Therefore, (i) increasing the high voltage makes the X-rays more penetrating (harder, shorter minimum wavelength); (ii) increasing the filament temperature increases the intensity of the X-rays without changing their quality.

  4. 4

    Question 4

    (i) Find maximum frequency of X-rays produced by an X-ray tube operating at a tube potential of 66 kV66\ \mathrm{kV}.

    (ii) State any one difference between characteristic X-rays and continuous X-rays.

    MediumAsked 2017
    2 marks
    Solve with AI
    Written solution

    Solution:

    Key idea: An electron accelerated through a potential difference VV gains energy eVeV. The highest-frequency X-ray photon is produced when all of this energy goes into one photon, so hνmax⁡=eVh\nu_{\max} = eV.

    Step 1 — Part (i): write the data with the paper's constants.

    We use e=1.6×10−19 Ce = 1.6 \times 10^{-19}\ \text{C} and h=6.6×10−34 J sh = 6.6 \times 10^{-34}\ \text{J s}, with the tube potential in volts.

    V=66 kVV = 66\ \text{kV}

    V=6.6×104 VV = 6.6 \times 10^{4}\ \text{V}

    Step 2 — Part (i): find the maximum frequency.

    We rearrange hνmax⁡=eVh\nu_{\max} = eV for νmax⁡\nu_{\max} and substitute.

    νmax⁡=eVh\nu_{\max} = \frac{eV}{h}

    νmax⁡=1.6×10−19×6.6×1046.6×10−34\nu_{\max} = \frac{1.6 \times 10^{-19} \times 6.6 \times 10^{4}}{6.6 \times 10^{-34}}

    νmax⁡=1.6×1019 Hz\nu_{\max} = 1.6 \times 10^{19}\ \text{Hz}

    Step 3 — Part (ii): give one difference.

    Continuous X-rays contain all wavelengths above a minimum wavelength λmin⁡\lambda_{\min}. That minimum depends only on the tube voltage, not on the target. Characteristic X-rays appear as sharp lines at a few definite wavelengths that depend only on the element of the target (they come from electron jumps between inner shells of the target atoms), not on the voltage.

    Therefore, (i) the maximum frequency of the X-rays is 1.6 × 10¹⁹ Hz; (ii) continuous X-rays have all wavelengths above a cut-off set by the tube voltage, whereas characteristic X-rays have a few sharp wavelengths that depend on the target element.