Which coil of a step up transformer is made thicker and why?
Previous Year Questions · Question 1 of 39
Which coil of a step up transformer is made thicker and why?
Solution:
Concept: A transformer works on mutual induction and only with a.c.: the changing current in the primary coil sets up a changing flux in the soft iron core, and this changing flux, linked with the secondary coil, induces an e.m.f. in it. The e.m.f. per turn is the same in both coils, so Es ÷ Ep is equal to Ns ÷ Np (the turns ratio). In an ideal transformer the power in equals the power out, so the current changes the opposite way: Is ÷ Ip is equal to Np ÷ Ns. In an ideal transformer the power going in equals the power coming out, so Es × Is is equal to Ep × Ip. The coil working at the lower voltage therefore carries the larger current.
Step 1 — Compare the voltages.
In a step-up transformer the secondary has more turns than the primary, so the secondary voltage is the higher one.
Step 2 — Compare the currents.
The power is (almost) the same in both coils, so the current ratio is the voltage ratio turned upside down.
Since Es is more than Ep, this ratio is more than 1, so the primary carries the larger current.
Step 3 — Choose the thicker coil.
A larger current heats a wire more (H = I²Rt). A thicker wire has less resistance, so making the primary of thick wire keeps this heating, the copper loss, small.

The figure shows the primary with few turns of thick wire (large current) and the secondary with many turns of thin wire (small current).
Watch out: In a step-UP transformer it is the PRIMARY that is thick; in a step-down transformer it is the secondary.
Therefore, in a step-up transformer the primary coil is made thicker, because it carries the larger current and a thick wire (low resistance) reduces the heating (copper) loss.