(i) Define coefficient of self-induction. Obtain an expression for self-inductance of a long solenoid of length l, area of cross-section A having N turns.
(ii) Calculate the self-inductance of a coil using the following data obtained when an AC source of frequency (π200) Hz and a DC source is applied across the coil.
Source
S. No.
V (volt)
I (ampere)
DC
1
4.0
1.0
DC
2
6.0
1.5
DC
3
8.0
2.0
AC
1
3.0
0.5
AC
2
6.0
1.0
AC
3
9.0
1.5
(i) The coefficient of self-induction L of a coil is the flux linked with the coil per unit current through it, NΦ=LI. Equivalently, it is the emf induced in the coil when its own current changes at 1A s−1, since ε=−LdI/dt.
Solenoid. Let the solenoid have length l, cross-section A and N turns, so n=N/l turns per metre, with a core of relative permeability μr (for air, μr=1).
The field inside is B=μrμ0lNI, uniform over the cross-section.
The flux through each turn is Φ=BA=μrμ0lNIA.
The flux linked with all N turns is NΦ=μrμ0lN2AI.
Hence
L=INΦ=lμrμ0N2A(=μrμ0n2Al)
(ii) With dc, the current is steady, the coil's inductance has no effect, and V/I is its resistance: R=4.0/1.0=6.0/1.5=8.0/2.0=4.0Ω.
With ac, V/I is the impedance: Z=3.0/0.5=6.0/1.0=9.0/1.5=6.0Ω.