(a) X = direct current (DC). A steady one-way current makes cations move to the cathode and anions to the anode, where they are discharged — this is electrolysis.
Y = alternating current (AC). AC (NCERT: 550–5000 Hz) reverses direction many times a second, so no net electrolysis or change in concentration takes place at the electrodes. This is why AC is used in a conductivity cell to measure conductivity.
(b) With inert (Pt) electrodes, copper is deposited at the cathode and oxygen is liberated at the anode.
At the cathode (reduction) — Cu2+ and H2O compete:
Cu2+(aq)+2e−→Cu(s)E∘=+0.34 V
2H2O(l)+2e−→H2(g)+2OH−(aq)E∘=−0.83 V
Cu2+ has the higher reduction potential, so it is reduced and copper is deposited.
At the anode (oxidation) — SO42− and H2O compete. Sulphate is very hard to oxidise, so water is oxidised:
2H2O(l)→O2(g)+4H+(aq)+4e−

Products: Cu at the cathode and O2 at the anode. The solution slowly turns into sulphuric acid (H+ and SO42− remain). (If copper electrodes are used instead, the copper anode dissolves, Cu→Cu2++2e−, and no oxygen is formed.)