A digital multimeter set to its diode-test range passes a small current (about 1 mA ) from its red probe, which is…

Question 233 marksMedium

A digital multimeter set to its diode-test range passes a small current (about 1 mA1\ \text{mA}) from its red probe, which is positive, to its black probe, and shows the voltage between the probes. It shows 'OL' if almost no current can flow. A technician tests four two-lead components P, Q, R and S and records these readings. (Hypothetical data.)

Componentred on lead 1, black on lead 2red on lead 2, black on lead 1
P0.62 VOL
QOL0.24 V
R0.00 V0.00 V
SOLOL

(i) For P and for Q, name the lead that is the anode.

(ii) Which of P and Q is a silicon diode, and which a germanium diode? Give a reason.

(iii) R and S are damaged diodes. State the fault in each.