Class 10 Physics Chapter 9 Household Circuits: Practice Questions
41 questions on Chapter 9, each worked through on its own page with the AI tutor. Class 10 Physics, ICSE 2026-27.
41 questions
1–5 marks · Mixed difficulty
- 11 mark
Question 1
Bloom's level: Remember
Which sequence correctly shows the voltage of the a.c. supply, step by step, from the generating station to a house ?
- 21 mark
Question 2
Bloom's level: Remember
The switch that controls a ceiling fan in a room is connected :
- 31 mark
Question 3
Bloom's level: Understand
An old house has wires with insulation of the old colours red, black and green. An electrician replaces them with a new cable having the new colours. Which new colour must take the place of each old one ?
- 41 mark
Question 4
Bloom's level: Apply
In a room, the switch of a bulb has been wrongly fitted in the neutral wire. With the switch OFF, a boy tries to change the bulb while standing barefoot on the floor. Which statement is correct ?
- 51 mark
Question 5
Bloom's level: Apply
A geyser rated 2 kW, 220 V is to be protected by a fuse. Fuses of 5 A, 10 A, 15 A and 20 A are available. Which is the smallest fuse that will let the geyser work normally ?
- 61 mark
Question 6
Bloom's level: Understand
In Rohan's flat, all the sockets of a room are fed by a ring main: the wires leave the distribution board, go round the room and come back to the board. Why can the electrician use thinner wires for the ring than for a single line feeding the sockets from one end ?
- 71 mark
Question 7
Bloom's level: Analyse
The earth wire of a washing machine with a metal body has broken off. Later, the worn insulation of its live wire lets the live wire touch the metal body. A person standing on a wet floor touches the body. What happens ?
- 81 mark
Question 8
Bloom's level: Analyse
A staircase light is controlled by two two-way switches, S₁ at the bottom and S₂ at the top, joined by two wires P and Q. Each switch can join its common terminal to P or to Q. At present the light is ON with both switches on wire P.

Which statement is correct ?
- 91 mark
Question 9
Bloom's level: Evaluate
A man is stuck to a faulty electric iron and is getting a shock. Four people suggest what to do first. Whose suggestion is the safest ?
- 101 mark
Question 10
Bloom's level: Understand
Read the Assertion (A) and the Reason (R) and choose the correct option.
Assertion (A): A mobile phone charger with a plastic body is usually fitted with a two-pin plug, while an electric iron is fitted with a three-pin plug.
Reason (R): The earth connection is needed where a person can touch a metal body that may become live because of a fault.
- 111 mark
Question 11
Bloom's level: Understand
Read the Assertion (A) and the Reason (R) and choose the correct option.
Assertion (A): Electric power is transmitted from the generating station as alternating current (a.c.) and not as direct current (d.c.).
Reason (R): The voltage of a.c. can be stepped up or stepped down easily by a transformer.
- 121 mark
Question 12
Bloom's level: Apply
Read the Assertion (A) and the Reason (R) and choose the correct option.
Assertion (A): An electric heater rated 1.5 kW, 220 V can be used safely in a circuit protected by a 5 A fuse.
Reason (R): The current drawn by an appliance of power on a supply of voltage is .
- 132 marks
Question 13
Bloom's level: Remember
At the distribution board, the house wiring is divided into two kinds of circuits. Name them, state the fuse rating used in each, and give one appliance that works on each.
- 142 marks
Question 14
Bloom's level: Apply
A power line carries a fixed amount of power. Its voltage is raised from 11 kV to 220 kV. By what factor does (a) the current in the line, and (b) the heat lost per second in the line, change ?
- 152 marks
Question 15
Bloom's level: Apply
A room on a 220 V lighting circuit with a 5 A fuse has four 60 W bulbs, two 75 W fans and a 120 W TV.
(a) Find the current when all of them are on. Is the fuse safe ?
(b) A 1000 W electric iron is now plugged into the same circuit with everything else on. What happens ? Give a reason.
- 162 marks
Question 16
Bloom's level: Understand
A switch and a fuse are both connected in the live wire of an appliance. State one similarity and one difference between them.
- 172 marks
Question 17
Bloom's level: Understand
A staircase light could be controlled by two ordinary on-off switches, one at each end. Explain why neither joining them in series nor joining them in parallel gives proper control from both ends.
- 182 marks
Question 18
Bloom's level: Remember
(a) State any two safety precautions to be taken while using electricity at home.
(b) Why must water never be thrown on an electrical fire ?
- 192 marks
Question 19
Bloom's level: Evaluate
A room heater rated 2.5 kW, 220 V has a 15 A three-pin plug, but the only socket in the room is a 5 A socket of the lighting circuit. A friend suggests using an adaptor to fit the plug into this socket. Is this a good idea ? Justify with a calculation.
- 202 marks
Question 20
Bloom's level: Analyse
While repairing the plug of a room heater, an electrician wrongly connects the brown wire to the earth terminal and the green/yellow wire to the live terminal of the plug. The plug is then put in the socket and switched on. What happens to (a) the metal body of the heater, and (b) the heating element ? Explain.
- 212 marks
Question 21
Bloom's level: Apply
Three appliances A (1100 W), B (440 W) and C (660 W) are connected to the ring circuit of a house on a 220 V supply, and all are switched on. Find the current through each appliance and the total current drawn from the supply.
- 222 marks
Question 22
Bloom's level: Apply
The main fuse of a house on a 220 V supply is rated 25 A.
(a) What is the largest total power that can be used at one time ?
(b) Can a 2.2 kW air conditioner, a 2 kW geyser, a 1.5 kW room heater and 300 W of lights all be used together ?
- 234 marks
Question 23
Bloom's level: Analyse
A power station sends 6.6 MW of power to a town through transmission lines of total resistance 8 Ω.
(a) Find the current in the line and the power wasted as heat in it if the power is sent at 11 kV.
(b) Repeat (a) for transmission at 132 kV.
(c) Express each loss as a percentage of the power sent, and find the fall in voltage along the line in each case.
(d) What do these results show about the choice of transmission voltage ?
- 244 marks
Question 24
Bloom's level: Apply
Case study: In a kitchen, a microwave oven (1200 W), a toaster (800 W) and an electric kettle (1500 W) are all plugged into one power circuit protected by a 15 A fuse. The supply is 220 V. One morning, when all three are switched on together, the supply to the kitchen goes off. A neighbour fixes it by putting a thick copper wire in place of the fuse wire.
(a) Find the current drawn by each appliance.
(b) Explain why the supply went off. Which two appliances can be used together safely ? Show a calculation.
(c) Why is the neighbour's repair dangerous, and what should have been done instead ?
- 255 marks
Question 25
Bloom's level: Create
Design the wiring for a bedroom light that can be switched on or off both from the door and from the bedside.
(a) Name the switches you will use and draw a labelled circuit diagram, showing the live wire, the neutral wire and a fuse.
(b) Make a table of all the possible switch positions and the state of the light in each.
(c) Explain where you placed the fuse and why the switches must be in the live wire.
- 264 marks
Question 26
Bloom's level: Analyse
Case study: Meera's electric iron has a metal body and a three-core cable. For some days she has felt a slight tingling when she touches the iron while standing barefoot. An electrician finds that inside the iron, the insulation of the live wire has worn and the bare wire touches the metal body, and that the earth wire was screwed onto a painted part of the body and has worked loose.
(a) Explain why Meera feels a tingling.
(b) Why did the fuse not blow ?
(c) The electrician first scrapes off the paint and fixes the earth wire tightly, but does not yet repair the live wire. What will happen when the iron is switched on ? Why is this better than before ?
- 273 marks
Question 27
Bloom's level: Understand
Explain the reason behind each of the following safety precautions :
(a) Old wires with cracked insulation should be replaced.
(b) Many appliances should not be run from one socket through a multi-plug adaptor.
(c) The main switch should be switched off before replacing a fuse wire.
- 284 marks
Question 28
Bloom's level: Evaluate
To save wire, a builder proposes that all the bulbs, fans and sockets of a flat be connected in series on a single wire, with one switch near the meter to control everything. Evaluate this plan. Give at least three reasons for your judgement, and state the system that should be used instead.
- 294 marks
Question 29
Bloom's level: Create
Construct a one-page reference table for a trainee electrician on the three wires of a household cable. For each wire give : its new colour, its old colour, its potential, which hole of a three-pin socket (seen from the front) it goes to, and the part of an appliance it is joined to. Below the table, write two short rules about where fuses and switches go.
- 305 marks
Question 30
Bloom's level: Apply
Case study: A new flat gets its supply from the pole through a company fuse, a kWh meter and a main switch, and then a distribution board with two MCBs: one for a 5 A lighting circuit and one for a 15 A power circuit. The supply is 220 V.
(a) The main switch is a double pole switch. Which wires does it disconnect, and why is this useful ?
(b) Sort these appliances into the lighting and the power circuit, giving a reason based on current: 40 W tube lights, 60 W ceiling fans, a 100 W TV, a 2 kW geyser, a 1 kW electric iron, a 2 kW room heater.
(c) Each day the family uses the geyser for 1 hour, four tube lights for 6 hours and three fans for 10 hours. How many units will the kWh meter record in a 30-day month for these appliances ?
- 312 marks
Question 31
An electrician puts a fuse of rating 5 A in that part of a domestic electrical circuit in which an electric heater of rating 3 kW, 220 V is operating. What is likely to happen in this case and why ?
- 321 mark
Question 32
At a generating station the voltage is stepped up from 11 kV to 132 kV before the power is sent through the line wires. For the same power transmitted, the current in the line wires at 132 kV, compared with the current at 11 kV, becomes :
- 331 mark
Question 33
An electric oven rated 1760 W, 220 V is to be connected to the mains through a fuse of its own. The most suitable current rating of the fuse is :
- 341 mark
Question 34
Assertion (A): The earth pin of a three-pin plug is made longer than the live and neutral pins.
Reason (R): The earth pin of a three-pin plug is made thicker than the other two pins so that it cannot enter the live or the neutral hole of the socket.
- 352 marks
Question 35
The cable from the pole reaches the distribution board of a house through three devices : the main switch, the kWh meter and the main fuse.
(i) Write these three devices in the order in which they are connected, starting from the pole.
(ii) Why is the main switch a double pole switch ?
- 362 marks
Question 36
In a house on the 220 V mains, a microwave oven of 1100 W, a refrigerator of 220 W and four fans of 55 W each are working at the same time.
(i) Are these appliances connected in series or in parallel with the mains ? Give one reason for connecting them in this way.
(ii) Calculate the total current drawn from the mains.
- 372 marks
Question 37
While wiring a room, an electrician connects the switch of a ceiling fan in the neutral wire by mistake.
(i) Will the fan still start and stop when the switch is put on and off ? Give a reason.
(ii) State why this connection is dangerous.
- 382 marks
Question 38
A three-core cable is used to connect an electric geyser to the mains.
(i) State the colours of the insulation of the live, neutral and earth wires of the cable according to the new international convention.
(ii) To which of these three wires is the metal body of the geyser connected, and in which wire is the fuse placed ?
- 394 marks
Question 39
An electric toaster with a metal body is rated 880 W, 220 V. It is connected to the 220 V mains through a three-pin plug and a 5 A fuse.
(i) Calculate the current drawn by the toaster in normal use.
(ii) Due to a fault, the live wire touches the metal body of the toaster. The resistance of the path from the live wire through the metal body and the earth wire is 4 Ω. Calculate the current that flows through this path.
(iii) Explain how the earthing and the fuse together protect a person who touches the toaster.
- 403 marks
Question 40
The diagram shows a lamp on a staircase controlled by two dual control switches S₁ and S₂. S₁ can touch the contact a or b, and S₂ can touch the contact c or d.

(i) Is the lamp on or off in the position shown ? Give a reason.
(ii) State the two different ways, each using only one switch, in which the lamp can be made to change its state.
(iii) State one advantage of using two dual control switches for a staircase lamp instead of a single ordinary switch.
- 414 marks
Question 41
A power circuit of a house on the 220 V mains is protected by a 15 A fuse. A geyser rated 2200 W, 220 V is working on this circuit.
(i) Calculate the current drawn by the geyser.
(ii) A room heater rated 1320 W, 220 V is now switched on in the same circuit while the geyser is working. Show by calculation what happens to the fuse.
(iii) State two precautions that should be taken to avoid such a situation or the damage it can cause.