Basis: taking logarithms of the Arrhenius equation k=Ae−Ea/RT:
lnk=lnA−REa⋅T1
So lnk against 1/T is a straight line with slope =−Ea/R and intercept =lnA.
Step 1: convert the data
| T / K | 273 | 293 | 313 | 333 | 353 |
|---|
| 103/T / K⁻¹ | 3.663 | 3.413 | 3.195 | 3.003 | 2.833 |
| k / s⁻¹ | 7.87×10−7 | 1.70×10−5 | 2.57×10−4 | 1.78×10−3 | 2.14×10−2 |
| lnk | −14.06 | −10.98 | −8.27 | −6.33 | −3.84 |
Step 2: the graph

Step 3: activation energy
The best straight line through the five points has
slope=−1.210×104 K
(Using the two end points instead: (2.833−3.663)×10−3−3.84−(−14.06)=−1.23×104 K, very close.)
Ea=−R×slope=8.314×1.210×104 J mol−1
Ea≈1.01×105 J mol−1=101 kJ mol−1
Step 4: pre-exponential factor
The line gives lnA=30.29 (equivalently, lnA=lnk+RTEa at any point on the line):
A=e30.29≈1.4×1013 s−1
Step 5: rate constants at 30 °C and 50 °C
lnk=30.29−T1.210×104
At 30 °C (T=303 K, 103/T=3.300):
lnk=30.29−39.94=−9.65⇒k=6.4×10−5 s−1
At 50 °C (T=323 K, 103/T=3.096):
lnk=30.29−37.47=−7.18⇒k=7.6×10−4 s−1
Sense check: 6.4×10−5 lies between the measured values at 20 °C and 40 °C (1.70×10−5 and 2.57×10−4), and 7.6×10−4 lies between those at 40 °C and 60 °C, as they must. Values read from a hand-drawn graph (e.g. Ea≈100–103 kJ mol−1) are equally acceptable.