One end of a U-tube containing mercury is connected to a suction pump and the other end to atmosphere. A small pressure difference is maintained between the two columns. Show that, when the suction pump is removed, the column of mercury in the U-tube executes simple harmonic motion.
Oscillations · Question 18 of 18
One end of a U-tube containing mercury is connected to a suction pump and the other end to atmosphere.
While the pump works, the mercury level is higher in the limb connected to the pump. When the pump is removed, both limbs are open to the atmosphere and the levels move towards each other, overshoot, and oscillate.
Let the mercury have density , let the tube have uniform cross-sectional area , and let be the total length of the mercury column (measured along the tube).

Restoring force. At some instant let the level in the left limb be a distance below the equilibrium level. Mercury is incompressible and the tube is uniform, so the level in the right limb is the same distance above it. The difference in levels is .
Both surfaces are at atmospheric pressure, so the mercury below the lower surface is balanced on the two sides; what is not balanced is the extra column of height in the right limb. Its weight drives the liquid back towards equal levels:
The minus sign shows that the force is opposite to the displacement of the surfaces.
Equation of motion. The whole column, of mass , moves together with the same speed along the tube, so
The acceleration is proportional to the displacement and opposite to it, so the mercury column executes simple harmonic motion, with
If is the length of mercury in each limb (so that when the bend is short), the period is
The period depends only on the length of the column, not on the density of the liquid or the area of the tube.