What is the principle of working of a moving coil galvanometer?
Torque on a Current-Carrying Loop - Moving Coil Galvanometer · Question 36 of 68
What is the principle of working of a moving coil galvanometer?
Solution:
Key idea: A current-carrying coil in a magnetic field experiences a torque . In a moving coil galvanometer the field is radial, so in every position of the coil.
Step 1 — Write the deflecting torque.
In the radial field the plane of the coil is always parallel to the field, so the torque on the coil is the same at every deflection.
Step 2 — Write the restoring torque.
As the coil turns through an angle , it twists the suspension (or spring), which gives a restoring torque proportional to the twist. Here is the torsional constant.
Step 3 — Balance the torques.
The coil comes to rest when the two torques are equal.
Since , , and are constant, the deflection is proportional to the current, so the current can be read off a linear scale.
Therefore, a current-carrying coil in a radial magnetic field experiences a torque NIAB, which is balanced by the restoring torque Cφ of the suspension, so the deflection φ = (NAB/C)I is proportional to the current.