The earth’s magnetic field does not affect the deflection in the moving coil galvanometer. Why?
Torque on a Current-Carrying Loop - Moving Coil Galvanometer · Question 17 of 68
The earth’s magnetic field does not affect the deflection in the moving coil galvanometer. Why?
Solution:
Key idea: The deflecting torque on the coil of a moving coil galvanometer is , so any field acting on the coil turns it in proportion to the field's strength. A weak extra field can only add a tiny extra torque.
Step 1 — Compare the two fields.
The earth's magnetic field at the surface is only about 25 to 65 μT (of the order of T). The permanent magnet of a galvanometer, with its soft iron core, gives a strong radial field of the order of 0.1 T in the gap where the coil moves.
So the galvanometer's own field is a few thousand times stronger.
Step 2 — See what this means for the deflection.
The torque from the earth's field on the coil is smaller in the same ratio, so it changes the deflection by a negligible amount. The reading is fixed by the strong radial field of the magnet and the restoring torque of the suspension.
Therefore, the earth's field does not noticeably affect the deflection because it is thousands of times weaker than the strong radial field of the galvanometer's magnet.