In step up transformer the turn ratio is . A Leclanché cell (e.m.f. V) is connected across the primary. Find the voltage in the secondary.
Alternating Current · Question 130 of 134
In step up transformer the turn ratio is 1 : 2 .
Solution:
Key idea: A transformer works by mutual induction. An emf is induced in the secondary coil only while the magnetic flux through it is changing, so the primary must carry a changing (alternating) current.
Step 1 — Describe the current from the cell.
A Leclanché cell is a source of direct current. Once the circuit is complete, the current in the primary coil is steady.
Step 2 — Describe the flux in the core.
A steady current produces a steady magnetic field, so the flux through the core, and through the secondary coil, does not change with time.
Step 3 — Apply Faraday's law to the secondary.
The emf induced in the secondary is set by the rate of change of the flux through its turns.
The flux is constant, so its rate of change is zero and the induced emf in the secondary is zero. The turns ratio makes no difference when nothing is changing.
Only at the instant the cell is connected or disconnected does the current change, and then a brief pulse of emf appears in the secondary. In practice the cell would simply drive a steady current through the low resistance of the primary winding and soon run down.
Watch out: Multiplying V by the turns ratio to get V is wrong. The turns-ratio rule holds only for a changing (a.c.) voltage.
Therefore, the steady voltage in the secondary is zero (apart from brief pulses at switch-on and switch-off).