11 kilowatts power can be transmitted in two ways
(i) 220 volts at 50 ampere and
(ii) 22000 volts at 0.5 ampere
Which is economical? Give reasons for your choice.
Confirming your payment
Sign up now and get 250 free tokens.
Alternating Current · Question 78 of 134
11 kilowatts power can be transmitted in two ways
(i) 220 volts at 50 ampere and
(ii) 22000 volts at 0.5 ampere
Which is economical? Give reasons for your choice.
Solution:
Key idea: The power lost as heat in the transmission line is , where is the line current and the line resistance. For the same power, a higher voltage means a smaller current.
Step 1 — Check that both ways carry the same power.
We multiply the voltage by the current for each way.
Both deliver 11 kW, so we compare only the losses.
Step 2 — Find the line loss for way (i).
Let be the resistance of the line wires. We put A into .
Step 3 — Find the line loss for way (ii).
We put A into .
Step 4 — Compare the two losses.
We divide the first loss by the second.
For example, if the line resistance were , way (i) would waste 2500 W (about 23 % of the power) while way (ii) would waste only 0.25 W. The small current of way (ii) can also be carried by thinner, cheaper wires.
Therefore, the second way (22000 V at 0.5 A) is economical, because its line loss is times smaller.