Why does a DC voltmeter and a DC ammeter cannot read AC?
Alternating Current · Question 51 of 134
Why does a DC voltmeter and a DC ammeter cannot read AC?
Solution:
Key idea: A DC voltmeter or ammeter (moving-coil type) responds to the average value of the current through it.
Step 1 — Find the average value of AC over one cycle.
During one half-cycle the alternating current flows one way, and during the next half-cycle it flows the other way with the same size. So its average over one complete cycle is zero.
Step 2 — Find the meter reading.
The deflecting torque on the meter's coil reverses with the current. The moving system cannot follow these rapid reversals, so it responds to the average torque, which is zero.
Therefore, a DC voltmeter and a DC ammeter cannot read AC: the average value of AC over one cycle is zero, so they show zero reading.