The loss of power in a transformer can be reduced by
Alternating Current · Question 25 of 134
The loss of power in a transformer can be reduced by
(A) increasing the number of turns in primary
(B) increasing AC voltage applied to primary
(C) using a solid core made of steel
- Correct answer
(D) using a laminated core of soft iron
Answer: (D) using a laminated core of soft iron
Key idea: The main power losses in a transformer are copper loss ( heating of the windings), eddy-current loss (currents induced in the core), hysteresis loss (energy used in magnetising the core again and again) and flux leakage. The core losses are cut by making the core of thin, insulated laminations of a magnetically soft material.
Step 1 — See how laminations reduce eddy-current loss.
The changing flux induces eddy currents in the core. Thin sheets insulated from each other break the large current paths, so the eddy currents and the heat they produce become much smaller.
Step 2 — See how a soft core reduces hysteresis loss.
A magnetically soft material such as soft iron has a narrow hysteresis loop. Little energy is lost each time the core is magnetised and demagnetised, so the hysteresis loss is small.
Why the other options are wrong:
- (A) is wrong: Changing the number of primary turns only changes the turns ratio and the output voltage; it does not reduce the core losses, and extra turns add winding resistance.
- (B) is wrong: A higher applied voltage drives a larger flux swing in the core, so the core losses grow instead of falling.
- (C) is wrong: In a solid core the eddy currents flow round large paths of low resistance, so the eddy-current loss is large; ordinary carbon steel is also magnetically hard, with a wide hysteresis loop, so the hysteresis loss rises too.
Note: Real power transformers use thin insulated laminations of silicon steel, a magnetically soft steel; the added silicon also raises the resistivity, which cuts the eddy currents further.
Note: The book prints "terms" and "steal" in the options; these are misprints for "turns" and "steel".
Therefore, the loss of power is reduced by using a laminated core of soft iron: option (D).