Solution:
Key idea: The mutual inductance is the flux linkage of the second coil per unit current in the first, M=I1N2ϕ2. For two coils wound on a common core of length l and area A, M=lμ0μrN1N2A. So M depends on the numbers of turns, on how much of one coil's flux links the other, and on the permeability of the medium that links them.
Step 1 — Increase the distance between the coils (part i).
The field of the first coil weakens with distance, so less of its flux passes through the second coil. For the same current I1, the flux linkage N2ϕ2 is smaller. Hence M decreases.
Step 2 — Decrease the number of turns (part ii).
Fewer turns in the first coil give a weaker field for the same current, and fewer turns in the second coil link less of that flux. Since M∝N1N2, both changes make M smaller. Hence M decreases.
Step 3 — Place a thin iron sheet between the coils (part iii).
Iron has a permeability hundreds to thousands of times that of air. The answer expected here uses M∝μ: the iron raises the permeability of the medium through which the flux links the two coils, so M increases.
Note: This holds when the iron gives the flux a high-permeability path that links both coils, as a common iron core does. A thin sheet lying across the gap tends to carry the flux sideways along itself, and with a.c. it also carries eddy currents, so in practice such a sheet can weaken the coupling, just as a copper sheet in the gap does.
Therefore, (i) M decreases, (ii) M decreases, and (iii) M increases, because the iron raises the permeability of the medium linking the two coils (assuming the iron links both coils, as a core does).