Answer: (A) MnO4− can be used in aqueous HCl
Key idea: An oxidant is suitable for titrating Fe²⁺ only if it oxidises Fe²⁺ and nothing else in the solution. An oxidant whose reduction potential is higher than that of Cl2/Cl− will also oxidise chloride ions.
Step 1 — Check permanganate in HCl.
The permanganate couple has E∘=1.51 V.
The chlorine couple has E∘=1.40 V, a lower value. So permanganate oxidises some Cl⁻ ions of the acid to Cl₂ as well as oxidising Fe²⁺. Extra permanganate is used up and the titre is too high, so this statement is incorrect.
Step 2 — Check dichromate in HCl.
The dichromate couple has E∘=1.38 V, below 1.40 V, so dichromate does not oxidise Cl⁻, but it is well above 0.77 V, so it does oxidise Fe²⁺. This statement is correct.
Step 3 — Check both oxidants in sulphuric acid.
Sulphate ions cannot be oxidised further by either oxidant, so in H2SO4 both permanganate and dichromate oxidise only Fe²⁺. Both of these statements are correct.
Why the other options are wrong:
- (B) is wrong: Dichromate (1.38 V) is below the chlorine couple (1.40 V), so it does not oxidise chloride; the statement is correct, so it is not the incorrect one.
- (C) is wrong: In sulphuric acid permanganate oxidises only Fe²⁺, so this correct statement is not the one asked for.
- (D) is wrong: In sulphuric acid dichromate also oxidises only Fe²⁺, so this statement is correct as well.
Note: Current tables give 1.51 V, 1.33 V and 1.36 V for the permanganate, dichromate and chlorine couples, which lead to the same conclusion.
Therefore, the only incorrect statement is that MnO₄⁻ can be used in aqueous HCl: option (A).