Can methyl orange be used as an indicator for the following titrations?
(i) Hydrochloric acid vs Sodium hydroxide
(ii) Hydrochloric acid vs Sodium carbonate
(iii) Acetic acid vs Sodium hydroxide.
Give reasons for your answers.
Confirming your payment
Sign up now and get 250 free tokens.
Equilibrium: Ionic Equilibrium · Question 151 of 244
Can methyl orange be used as an indicator for the following titrations?
(i) Hydrochloric acid vs Sodium hydroxide
(ii) Hydrochloric acid vs Sodium carbonate
(iii) Acetic acid vs Sodium hydroxide.
Give reasons for your answers.
Solution:
Key idea: An indicator is suitable only if its colour-change range lies inside the steep jump in pH that occurs at the equivalence point of the titration. Methyl orange changes colour between pH 3.1 (red/pink) and 4.4 (yellow), on the acidic side.
Step 1 — (i) Judge HCl against NaOH. This is a strong acid–strong base titration.
The salt NaCl does not hydrolyse, so the equivalence point is at pH 7, and the pH jumps very steeply on either side of it. For 0.1 M solutions the pH rises from about 3.3 at 99 % neutralisation to about 10.7 at 101 %, all within a fraction of a millilitre. The methyl orange range (3.1–4.4) lies inside this jump, so yes, methyl orange can be used (as can phenolphthalein).
Step 2 — (ii) Judge HCl against Na₂CO₃. Sodium carbonate is the salt of a weak acid and a strong base and behaves as a weak base, so this is a strong acid–weak base titration. When it is fully neutralised, carbon dioxide (carbonic acid) is formed.
The solution at this end point contains dissolved carbonic acid and has a pH of about 4, which lies in the methyl orange range. So yes, methyl orange is the suitable indicator for complete neutralisation. (Phenolphthalein would show only the first stage, to , near pH 8.3.)
Step 3 — (iii) Judge acetic acid against NaOH. This is a weak acid–strong base titration.
At the equivalence point the sodium acetate hydrolyses, so the solution is alkaline. For 0.1 M solutions the salt is 0.05 M at the end point, and using :
The steep part of the curve lies roughly between pH 7 and 10. Methyl orange changes colour at pH 3.1–4.4, long before the end point (it would turn yellow when only about one-third of the acid has been neutralised), and its change is gradual. So no, methyl orange cannot be used; phenolphthalein (range 8.3–10.0) is used instead.
Therefore, methyl orange can be used for (i) HCl vs NaOH and (ii) HCl vs Na₂CO₃, because their end points or pH jumps include pH 3.1–4.4, but not for (iii) acetic acid vs NaOH, whose end point is alkaline (pH ≈ 8.7), so phenolphthalein is used there.